农药草甘膦生产废水处理的研究(1)
2014-10-06 01:08
导读:理工论文论文,农药草甘膦生产废水处理的研究(1)应该怎么写,有什么格式要求,科教论文网提供的这篇文章是一个很好的范例:
摘要:运用微电解絮凝床预处理和uasb-sbr组合处理草甘膦废水。
摘要:运用微电解絮凝床预处理和uasb-sbr组合处理草甘膦废水。试验结果表明;当进水ρ(codcr为26000-30000 mg/l,ρ(cl-)为 33000-35 000 mg/l时,处理后出水ρ(codcr)小于 130 mg/l,codcr平均去除率可达 99%以上。
关键词:草甘膦 废水处理 微电解 厌氧 好氧 a test of treatment of wastewater from pesticide giyphosate production
abstract:a treatment of wastewater from glyphosate production, which used a combined process of
pre-treatment with a microelectrolytic flocculating bed and uasb-sbr, was tested.the results of the test showed that when the ρ(codcr) of the inlet water was 26000~30000 mg/l and the ρ(cl-)was 33000~35000 mg/l, the p(codcr) of the outlet water after the treatment was below l30 mg/l and the codcr removal rate was over 99%.
key words: glyphosate; wastewater treatment; microelectrolysis; anaerobic; aerobic 草甘膦废水是化工农药行业生产草甘膦粉剂、水剂过程中排出的有机高浓度含重金属废水。生产草甘膦的主要原料有二乙醇胺、片碱、去离子水、盐酸、甲醛、三氯化磷、30%液碱、重金属催化剂、双氧水、钨酸钠、液氨、硫酸亚铁等。1 废水水质与试验工艺1.1 废水水质
草甘膦生产过程中各部分废水混合后的水质情况见表1。
表1 草甘膦混合废水水质情况项 目参 数
ph值2.5~3.8
ρ(codcr)/(mg·l-1)26000~30000
ρ(bod5)/(mg·l-1)17680~20000
ρ(cl-)/(mg·l-1)33000~35000
ρ(nh3-n)/(mg·l-1)15.6~31.6
ρ(∑cu)/(mg·l-1)125.3~330.2
ρ(∑ni)/(mg·l-1)3.95~4.50
从表1可看出该废水m(bod5)/m(codcr)比值约为0.68,可生化性较好,主要为溶解性有机物,采用生物处理较为合理。但废水中含有高达35000mg/l的cl-和大量重金属离子,使生化反应受到严重抑制,甚至根本无法进行。有人有电解反应器加选择性生物反应器等工艺尝试去除cl-对微生物的干扰,取得较好效果[1]。针对该废水特点我们采用微电解预处理与上流式厌氧污泥床(uasb)、好氧sbr、活性污泥法相结合的组合工艺对该废水进行连续处理试验。
(转载自http://zw.nseac.coM科教作文网)
1.2 试验工艺
草甘膦废水试验工艺流程如图1所示。

废水首先进入调节池进行混合调节后,用不锈钢泵打入微电解絮凝床,经过适当停留时间后流人中和沉淀池,投加碱液调整ph至6-9,机械搅拌混凝沉淀以除去废水中的重金属和绝大多数cl-和h ,并除去大部分codcr。上清液流入uasb池中,利用厌氧菌的生物降解作用对污染物进行有效去除。出水进人sbr系统进行好氧处理,处理后可达标排放。
1.3 主要设备
微电解絮凝床为钢结构,防腐,底部设有进水有水器,内部填充按一定比例配制的铸铁屑、粗制活性炭和疏松剂。出水通过集水槽汇入中和沉淀系统。
uasb为钢结构,防腐,底部设有进水布水器,内设三相分离器,外部采用泡沫塑料层保温。
sbr反应器,内设曝气装置,按进水、曝气、沉淀、浇水、闲置的程序周期运行。
2 试验结果分析
2.2 微电解絮凝床 中和沉淀系统
微电解絮凝床反应机理较为复杂,而且本身内部发生一系列物理
化学作用。基本认为当有一定电位差的铸铁屑和粗制活性炭浸没在废水溶液中,废水充当电解质,构成无数个微电池回路,在它的表面有电流流动,产生电极反应和由此引起的一系列作用,改变废水中污染物的性质,从而达到废水处理的目的。本研究中草甘膦废水的部分反应可能如下: